Trang nhất
Thiết bị công nghiệp, tự động hóa
Mạch điều khiển van GAMX-2007, Actuator Control Board, Bernard Control Board GAMX-2007
Đăng ngày 21-11-2018 04:32:34 PM - 293 Lượt xem
Mã sản phẩm: GAMX-2007
GAMX-2007 Bernard Electric ActuatorPosition locator isolation module instruction manual First, the main technical parameters1, input signal: 4-20mA 2, input resistance 250 ohms3, the output signal: 4-20mA, the input signal and the output signal are isolated, the user does not need to isolate the module4, output resistance: 0-500 ohms (special need 0-750 ohms)5. Feedback potentiometer: 0-1K ohm 6. Basic error: ±1%7, dead zone: 0-3% adjustable 8, power supply voltage: 220V ± 10%9, ambient temperature: -25 ° C - +55 ° C 10, relative humidity: ≤ 90% (no condensation)Second, the main function1. Operation mode: Forward: 4 mA valve is closed, 20 mA valve is open Reverse: 4 mA valve is open, 20 mA valve is closed.2. Interrupt hold: When the signal is lost, the actuator can remain in the home position, closed or open, and the interrupt signal setting actuator remains in the home position at the factory.3. Manual operation of the machine: The manual operation of the machine is to make the positioner simulate a 4-20 mA input signal, so that the actuator can be manually adjusted to fully open or close.4, 0% position: positioner 0%, so that the actuator is fully closed.5, 100% position: the positioner is 100%, so that the actuator is fully open.6. When the terminals 19 and 34 are shorted , the automatic control is turned off, and the manual is turned into the short circuit. The terminals 34 and 35 are manually turned off, and the short terminals 34 and 36 are manually opened. Remote control takes precedence over automatic control. When the controller is in the remote control position, the automatic control is blocked and does not work. The remote control is jog.7, actuator running direction:In standard form : the actuator (for the output shaft) is turned clockwiseThe DIP switch can be used to change the control (change the direction of motor rotation) to turn the actuator counterclockwise and change the direction of the limit switch and torque switch. 8, electric brake configuration: GAMX-2005 module 220VAC and 380VAC universalSingle phase power supply ( 220VAC) with electric brakeThe three-phase power supply ( 380VAC) makes the electric brake function ineffective through the dial switch, and the actuator electric brake is completed by the external circuit.9, LED instructions:LED1 ( red) power indicator LED 2 (green) actuator on LED3 (red) actuator offLED4 (red) loses 4-20mA signal LED5 (red) over torque switchLED6 (red) electric brake works, the brake light flashes instantly10. Use of DIP switch DIL 11, Slide switch COMV implements four states 12, P1 : adjust P1 clockwise to adjust the valve to close, counterclockwise to open the valve, at this time COMV must be in theMAN position13, P2 : 100 % full scale adjustment. Adjust the feedback current clockwise to increase, at this time COMV is in the AUTOposition.14, P3 : dead zone adjustment reference value: clockwise adjustment P3 , dead zone increase, low sensitivity, counterclockwise adjustment P3 dead zone reduction, high sensitivity, actuator in the automatic adjustment state, adjust the P3 potentiometer to make the actuator The best state is when the vibration is not oscillated and the highest sensitivity is reached. At this time, theCOMV is in the AUTO position.15, Short circuit sub- INV1 Third, the debugging method: The actuator works in the machine to automatically adjust the working state, use the remote control terminals 34 , 35 , 36 to fully close the actuator, adjust the position potentiometer, make the feedback current 4mA , make the actuator fully open, adjust the full potentiometer P2 makes the feedback current 20mA , repeat the above operation several times, until the actuator is fully closed corresponding to the feedback current 4mA , fully open corresponding to the feedback current 20mA .
CÔNG TY TNHH CÔNG NGHỆ SỐ TÂN THÀNH
Trụ sở: Số 189, Nguyễn Văn Linh, P. Kênh Dương, Q.Lê Chân, TP Hải Phòng
VP giao dịch: số 165, Thiên Lôi, P.Vĩnh Niệm, Q.Lê Chân, TP.Hải Phòng
Tel: 0225.8830.305 Fax: 0225.8830.305
Kinh doanh 1: 091.686.1515 - 081.686.1515
Kinh doanh 2: 091.797.1515 - 083.797.1515
Website: http://Tanthanhtech.com
Website: http://tanthanh-automation.com
Email: Tanthanhdigitech@gmail.com
Xin chân thành cảm ơn và hi vọng được hợp tác cùng quý khách!
-
-
Công tắc hành trình, công tắc giới hạn LX36-82,LX36-84,LX36-88
Liên hệ
-
-
Mạch Nguồn cho cân A&D AD-4404 ,AD4404, PZ3502
Liên hệ
-
-
Van điện từ, SMC solenoid valve SQ1141Y-5LO-C4 SQ1141Y-5LO-C4-X30-Q SQ1141Y-5LO1-C6
Liên hệ
-
-
Tiếp điểm động máy cắt chân không, má dao, moving contact GC6-400A 8 , GC6-630A 12, GC6-1000A 20,GC6-1250A 24,GC6-1600A 28,GC6-2000A 32 ,
Liên hệ
-
-
Tiếp điểm khởi động từ, CJX2-4011 / LC1-D40 CJX2-5011 / LC1-D50 CJX2-6511 / LC1-D65 CJX2-8011 / LC1-D80 CJX2-9511 / LC1-D95 CJX2-3210 / LC1-D32
Liên hệ
-
-
Cylinder TPM TSC ,Xy-lanh TPM TSC TSC50X25 TSC50X75 TSC50X100 TSC50X125 TSC50X150 TSC50X175 TSC50X200 TSC50X250 TSC50X300 TSC50X350 TSC50X400 TSC50X450 TSC50X500 TSC50X600 TSC50X700 TSC50X800 TSC50X900 TSC50X1000 TSC50X50
Liên hệ
-
-
Đồng hồ kẹp dòng, VICTOR victory digital clamp meter multimeter VC6052, VC6050 VC6056A+ AC and DC clamp meter
Liên hệ
-
-
Cảm biến tải, cảm biến cân, loadcell , Weighing Sensor ,Vishay Celtron HBB
Liên hệ
-
-
Van điện từ khí nén, solenoid valve AIRTAC 3V110-06, 3V210-08,3V210-06, 3V310-08, 3V310-10 ,4V110-M5
Liên hệ
-
-
Mạch main, Main PCB Mettler Toledo IND780 Part 64084167 EXT-Board 64084167
Liên hệ
-
-
Thanh đấu nối cáp, Patch Panel AMP 16 Port Cat5E Chính hãng
950.000đ
-
-
Schneider ATS48 series soft start 160kw ATS48C32Q driver board
Liên hệ