Order number: 2489680000 Model: ACT20P-CI-CO-P
Input signal: 0(4)...20mA Output signal: 0(4)...20mA
• 24Vdc power supply
• Isolation voltage 2kVac
• Can supply power to field transmitters
• Three-terminal isolation of input, output and power supply
• Product width 12.5mm
Screw connection
ACT20P-CI-CO-P
Icon Icon Icon Icon Icon
Order data
Type ACT20P-CI-CO-P
Order number 2489680000
Version signal transmitter/isolator, input: 0(4)-20 mA, output: 0(4)-20 mA
GTIN (EAN) 4050118535150
Quantity 1 pc(s).
Available inventory
Dimensions and weight
Width 12.5 mm
Width (inch) 0.492 inch
Height 127.1 mm
Height (inch) 5.004 inch
113.7 mm deep
Depth (inch) 4.476 inch
Weight 110 g
Net weight 120 g
temperature
Minimum storage temperature. -40 °C
Minimum operating temperature -20 °C
Maximum storage temperature 85 °C
Maximum operating temperature 60 °C
Humidity 5...95 %, non-condensing
Operating temperature -20 °C...60 °C
Storage temperature -40 °C...85 °C
Product environmental compliance
REACH SVHC Lead 7439-92-1
enter
Input number 1
Sensor power supply > 17 V DC when 20 mA, max 30 V @ open circuit, max 50 mA @ short-circuit
Input signal 2-/3-wire transmitter, two-way HART® signal
Input current 0...20 mA, 4...20mA
Voltage drop ≤ 1V
Output
Number of output channels 1
Output current 0...20 mA, 4...20 mA, HART® digital signal
Current load resistance ≤ 550Ω
in summary
Power supply voltage 20…30 V DC
Rail TS 35
Temperature coefficient 80 ppm/K
Current consumption ≤60 mA (24V power supply, 20mA output)
Accuracy <0.1% of final value
Insulated three-way splitter, between input/output/power
Configuration None
Step response time ≤ 0,5 ms
Insulation parameters
EMC standards EN 61010-1:2011, UL 61010-1, EN 61326-1
Shock resistance 4 kV (1.2 / 50 µs)
Pollution degree 2
Insulated three-way splitter, between input/output/power
Insulation voltage 2 kV input/output/power supply
Overvoltage category III
Connection parameters
Connection type PUSH IN
Minimum wire crimping area AWG AWG 26
Maximum wire crimping area AWG AWG 14
The minimum crimping area of a single wire is 0.2 mm²
Maximum cross-section of single-stranded conductor 2.5 mm²
Minimum crimping area for flexible wires 0.2 mm²
Maximum crimping area for flexible wires 2.5 mm²
Wire connection cross-section, multiple thin wires, with tubular end DIN 46228/4, minimum 0.2 mm²
Wire connection cross-section, multiple thin wires, with tubular end DIN 46228/4, max. 2.5 mm²
product information
Product information The non-adjustable DC isolation amplifier ACT20P-CI-CO can isolate standard analog current signals from the power supply or 2 or 3 sensors. The analog input current signal is converted into an analog output current signal in a linear manner and electrically isolated. The power supply is electrically isolated from the input and output (3-terminal isolation).
Attributes
• HART-compatible range is 0.5-2.5 kHz
• The active or passive mA signal input is fully electrically isolated.
• Front panel LED has running status display
• 3-terminal electrical isolation between input, output and power supply.
download
Certification/Certificate/Declaration of Conformity
Declaration of Conformity
Engineering data
STEP
User documentation
Instruction sheet
classification
ETIM 6.0 EC002653
ETIM 7.0 EC002653
eClass 9.0 27-21-01-20
eClass 9.1 27-21-01-90
eClass 10.0 27-21-01-20
Certification
Certification CE EAC
Certification CULUS;
ROHS consistent