product description
HBM C16i Digital Load Cell
Overview
-
Eccentric load compensation for platform scales or truck scales: Sensitivity adjustment through software without welding resistance.
-
Stronger maintenance function: TRADE® software makes system diagnosis more convenient, even remote operation via telephone.
-
Reduce hardware requirements, without weighing display and necessary alibi printer.
-
Lower noise: digital signal transmission.
TRADE® software – PTB test certificate D09-00.34 – the agreement for indexing and judging the displayed and stored data.
In addition, the DDE interface can exchange data with other software.
For many weighing instrument manufacturers, what needs to be done is to reset the logistics software and let it communicate with the weighing indicator and the TRADE® software. The
C16i digital load cell and the analog sensor C16A have the same size. Therefore, for the weighing instrument Digital transformation is very convenient.
Widely used in truck scales, large weighing and batching places
technical parameter
model | C16i D1 | C16i C3 |
Rated capacity (Emax) | 20t | 30t | 40t | 60t | 20t | 30t | 40t | 60t |
Accuracy class | D1 (0.0330%) 1000 | C3 (0.0180%) 3000 |
Verification scale value (vmin) | % of Emax | 0.0200 | 0.0100 | 0.0083 |
Scale verification division value [... LC = max. Number of load cells] | kg | - | - | - | - | 5 [6 LC] 10 [10 LC] | 10 [10 LC] | 10 [6 LC] 20 [10 LC] | 10 [4 LC] 20 [10 LC] |
Sensitivity (Cn) | digit | 1 000 000 |
Sensitivity error | % | ≤± 0.0100 |
Temperature influence on sensitivity (TKC) 1) | % of Cn / 10K | ≤± 0.0250 1) | ≤± 0.0080 1) |
Influence of temperature on zero point | ≤± 0.0285 | ≤± 0.0140 | ≤± 0.0116 |
Hysteresis error | % of Cn | ≤± 0.0330 1) | ≤± 0.0170 1) |
Linearity error | ≤± 0.0300 1) | ≤± 0.0180 1) |
Creep error | ≤± 0.0330 | ≤± 0.0167 |
Reference excitation voltage | V (DC) | 12 |
Rated excitation voltage | 7 ... 15 2) |
Current consumption | mA | 50 2) |
Index | Bit | 20 (at 1Hz) |
Measuring rate | / sec | 100 50 25 12 6 3 2 1 |
Filter mode 0 | Hz | 80.05 (Low pass filter) |
Filter mode 1 | 8 ... 3 (Low pass filter) |
Asynchronous connection | | RS-485 / 4-wire (Cable lenght up to 500m) |
Baud rate | Baud | 1200 ... 38400 |
Number of bus addresses | | max. 32 |
Rated temperature | °C [°F] | - 10 ... +40 [14 ... 104] |
Operating temperature | - 20 ... +70 [-4 ... 158] |
storage temperature | - 50 ... +85 [-58 ... 185] |
Extreme load | % of Emax | 150 |
Destruction load | > 350 |
Allow dynamic load | 70 |
Deformation under full scale load | mm | 0.65 | 0.75 | 0.85 | 1.22 | 0.65 | 0.75 | 0.85 | 1.22 |
weight | kg | 2.2 | 2.4 | 3.0 | 3.8 | 2.2 | 2.4 | 3.0 | 3.8 |
Protection level | | IP68 (test conditions 100h at 1m water column) IP69K (water at high pressure, steam jet cleaning) |
Material | | Stainless steel neoprene thermoplastical elastomer |
1) The data for Non - Linearity (dlin), Hysteresis error (dhy) and Temperatureeffect on sensitivity (TKC) are typical values. The sum of these data meets the requirements for pLC = 0.8 according to OIML R60.
2) Please refer to the power supply table in the Installation instructions!
Installation dimension drawing
![](https://img.alicdn.com/imgextra/i2/2200628380601/O1CN019dpyUS1GJIbQYLzN0_!!2200628380601.jpg)
![](https://img.alicdn.com/imgextra/i4/2200628380601/O1CN015382ld1GJIbO5nviO_!!2200628380601.jpg)